Currently Viewing
  • Narrow by
  • Application Area
    • Control

IPNet Results

Field-Oriented Controller (FOC) / Space-Vector Controller for a Brushless DC Motor
EXAMPLE - Field-Oriented Controller (FOC) / Space-Vector Controller for a Brushless DC Motor - This document contains the following FPGA IP: Field-Oriented Control ...
Rating: 4.80
Author: Ben_B
Last Modified: September 12 2009
Number of Comments: 3
Number of Downloads: 5,690
decibel.ni.com/content/docs/DOC-2386
Fail-Safe Control Reference Design for CompactRIO
This example provides a framework for control systems which must behave predictably in the event of a hardware or software failure. The example demonstrates FPGA ...
Rating: 5.00
Last Modified: April 19 2010
zone.ni.com/devzone/cda/epd/p/id/5984 Download
Look-up Table for Sinusoidal (V/f) Control of a Brushless DC Motor
EXAMPLE - Look-up Table for Sinusoidal (V/f) Control of a Brushless DC Motor - This block of FPGA code computes three PWM outputs for the three legs of a 6-FET bridge ...
Rating: 5.00
Author: Ben_B
Last Modified: September 12 2009
Number of Comments: 0
Number of Downloads: 2,660
decibel.ni.com/content/docs/DOC-2385
6-Phase (Trapezoidal) Control for Brushless DC Motors
EXAMPLE - 6-Phase (Trapezoidal) Control for Brushless DC Motors - This piece of code represents the simplest method for controlling a brushless DC (BLDC) motor, ...
Rating: 5.00
Author: Ben_B
Last Modified: October 28 2008
Number of Comments: 1
decibel.ni.com/content/docs/DOC-2424
Angle Measurement of a Crank and Cam Signal
EXAMPLE - Angle Measurement of a Crank and Cam Signal - In this example, pulses are calculated by checking for rising (crank) or falling (cam) zero crossings. Keep ...
Rating: 0.00
Author: SteakMcDAX
Last Modified: December 10 2008
Number of Comments: 1
decibel.ni.com/content/docs/DOC-2941
Half-Bridge Control
EXAMPLE - Half-Bridge Control - This block of FPGA code can be used to directly control the digital switches (either FETs or IGBTs) in a half-bridge. The block uses ...
Rating: 0.00
Author: Ben_B
Last Modified: September 12 2009
Number of Comments: 0
Number of Downloads: 1,525
decibel.ni.com/content/docs/DOC-2382
PID Control Reference Example for LabVIEW FPGA
This example shows how to do simple PID control of a PWM output using an analog input as feedback.
Rating: 3.25
Last Modified: April 19 2010
zone.ni.com/devzone/cda/epd/p/id/5814 Download
Relay VI - LabVIEW 2011 FPGA Module Help
Switches between the output when on and output when off inputs. When the relay is on, it remains on until input is less than switch off point. When the relay is ...
zone.ni.com/reference/en-XX/help/371599G-01/lvfpga/fpga_relay/
Quantizer Express VI - LabVIEW 2011 FPGA Module Help
Round to nearest—The default rounding mode. LabVIEW rounds to the value nearest the original input while setting the lowest bits, specified by Interval (bits), to ...
zone.ni.com/reference/en-XX/help/371599G-01/lvfpga/fpga_quantizer/
Basic Discrete Delay Express VI - LabVIEW 2011 FPGA Module Help
Inputs the data point the VI returns when first called or when initialize is TRUE. The VI returns initial condition every call after initialization until the loop ...
zone.ni.com/reference/en-XX/help/371599G-01/lvfpga/discrete_delay/
Title
Application Area
Part of
LabVIEW Version
Field-Oriented Controller (FOC) / Space-Vector Controller for a Brushless DC Motor Control Community 8.6 3
Fail-Safe Control Reference Design for CompactRIO Control Example 8.5.1 4
Look-up Table for Sinusoidal (V/f) Control of a Brushless DC Motor Control Community 8.5,8.6 4
6-Phase (Trapezoidal) Control for Brushless DC Motors Control Community 8.6 4
Angle Measurement of a Crank and Cam Signal Control Community 8.6 3
Half-Bridge Control Control Community 8.6 4
PID Control Reference Example for LabVIEW FPGA Control Example 8.5 3
Relay VI - LabVIEW 2011 FPGA Module Help Control 8.0-2011 5
Quantizer Express VI - LabVIEW 2011 FPGA Module Help Control 8.0-2011 5
Basic Discrete Delay Express VI - LabVIEW 2011 FPGA Module Help Control 8.0-2011 5

IPNet Results

Search Syntax Summary

OperatorExampleActionBoolean Equivalent
" " "temperature monitoring" Requires two terms to be adjacent to each other. In this example, only documents containing the phrase "temperature monitoring" will be shown. ADJ
+ +temperature Requires this term to be present as-is, eliminating the use of synonyms. This search query can be used in conjunction with other keywords to find only documents containing the word "temperature". AND
- -monitoring Excludes results containing this term. Use this query in conjunction with other terms to find only documents not containing the word "monitoring" NOT
() (temperature monitoring) Allows terms to be grouped when used with other operators. For example, searing for industrial -(temperature monitoring) will return only documents containing "industrial" but not "temperature" or "monitoring" OR
* monitor* Acts as a wildcard. This example will return documents containing words "monitor", "monitoring", "monitored", etc n/a

Basic Tips

  • Search is not case sensitive. Searching for LabVIEW is the same as searching for labview.
  • Keep your query short and focused, including all relevant keywords. For example, searching for labview error is much more vague than labview error 1041.
  • Usually, all punctuation and special characters are interpreted as delimiters and are ignored. See exceptions on the Syntax page. Be especially careful when using a minus sign in front of an error number, as it excludes it from the results.
  • Search for keywords you would expect to see on a page. For example, terms pxi does not work are unlikely to appear in technical documentation. The query like analog output noise will return better search results.

Advanced Tips

  • You locale settings identify your current geographical location and affect your search results. For example, if you set your country to Japan, Japanese documents will get boosted in your search results. Check your locale settings in the top right corner of the search page.