NI Code Exchange Results

Wireless Medical Device Testing with LabVIEW
RF wireless medical devices can interfere with each other. If a collision between their respective transmissions occurs, data packets transmitted by medical devices ...
Rating: 0.00
Last Modified: May 08 2013
zone.ni.com/devzone/cda/epd/p/id/6565
Audio Analyzer (NI-DAQmx) (Sound and Vibration)
Audio Analyzer (NI-DAQmx) (Sound and Vibration) is an interactive application example used to configure DAQmx hardware, perform audio measurements, and inspect time ...
Rating: 5.00
Last Modified: November 09 2012
zone.ni.com/devzone/cda/epd/p/id/6563 Download
Medical Coexistence Testing Methods for Bluetooth and WLAN
In wireless coexistence scenarios, two or more collocated devices transmit data sharing available time and frequency resources. The FDA has issued a draft guidance ...
Rating: 0.00
Last Modified: May 08 2013
zone.ni.com/devzone/cda/epd/p/id/6572
Dynamically Add, Delete and Configure WSN Nodes on the NI 9792 Programmable WSN Gateway
This application provides a single interface to dynamically add, delete and configure WSN nodes on the NI 9792 gateway.
Rating: 5.00
Last Modified: September 14 2011
zone.ni.com/devzone/cda/epd/p/id/6480 Download
Wheatstone Bridge Based Measurements with myDAQ and LabVIEW
This document explains using Wheatstone Bridge to make a precise measurement for sensors such as strain gauges and load cells. The data will be acquired using the ...
Rating: 3.75
Last Modified: March 29 2013
zone.ni.com/devzone/cda/epd/p/id/6417
Dorm Room Alarm System Using a PIR Motion Detector, Speakers, myDAQ, and LabVIEW
This document explains using a PIR Motion Detector with Computer Speakers to play an Alarm when motion is detected with your National Instruments myDAQ in LabVIEW. ...
Rating: 3.67
Last Modified: July 23 2010
zone.ni.com/devzone/cda/epd/p/id/6405
Wireless Solar Monitoring Starter Kit
Field monitoring of solar installations enables operators to maximize revenue generation and reduce operation and maintenance costs. This application note includes ...
Rating: 3.47
Last Modified: December 08 2010
zone.ni.com/devzone/cda/epd/p/id/6452 Download
Configuration Benchmarking Tool for NI VeriStand
The configuration benchmark tool for NI VeriStand redeploys a system configuration to a NI Real-Time (RT) target until the highest stable loop rate is found. A binary ...
Rating: 0.00
Last Modified: April 02 2013
zone.ni.com/devzone/cda/epd/p/id/6441
Semaphore Reference Design for LabVIEW FPGA
When developing applications using LabVIEW FPGA it becomes necessary to use shared resources such as a local and global variables, non-reentrant VIs, etc. in multiple ...
Rating: 5.00
Last Modified: May 06 2010
zone.ni.com/devzone/cda/epd/p/id/6014 Download
CANopen Reference Example for the NI-9853 C-Series CAN Module
The CANopen protocol is a higher level protocol which is based on CAN, a message-based bus protocol which facilitates communication between devices typically on ...
Rating: 5.00
Last Modified: January 09 2013
zone.ni.com/devzone/cda/epd/p/id/6093

NI Code Exchange Results

Search Syntax Summary

OperatorExampleActionBoolean Equivalent
" " "temperature monitoring" Requires two terms to be adjacent to each other. In this example, only documents containing the phrase "temperature monitoring" will be shown. ADJ
+ +temperature Requires this term to be present as-is, eliminating the use of synonyms. This search query can be used in conjunction with other keywords to find only documents containing the word "temperature". AND
- -monitoring Excludes results containing this term. Use this query in conjunction with other terms to find only documents not containing the word "monitoring" NOT
() (temperature monitoring) Allows terms to be grouped when used with other operators. For example, searching for industrial -(temperature monitoring) will return only documents containing "industrial" but not "temperature" or "monitoring" OR
* monitor* Acts as a wildcard. This example will return documents containing words "monitor", "monitoring", "monitored", etc n/a

Basic Tips

  • Search is not case sensitive. Searching for LabVIEW is the same as searching for labview.
  • Keep your query short and focused, including all relevant keywords. For example, searching for labview error is much more vague than labview error 1041.
  • Usually, all punctuation and special characters are interpreted as delimiters and are ignored. See exceptions on the Syntax page. Be especially careful when using a minus sign in front of an error number, as it excludes it from the results.
  • Search for keywords you would expect to see on a page. For example, terms pxi does not work are unlikely to appear in technical documentation. The query like analog output noise will return better search results.

Advanced Tips

  • You locale settings identify your current geographical location and affect your search results. For example, if you set your country to Japan, Japanese documents will get boosted in your search results. Check your locale settings in the top right corner of the search page.