Creating Virtual Channels with the API - NI-DAQmx 17.6 Manual https://www.ni.com/documentation/en/ni-daqmx/17.6/mxcncpts/createchansapi/
The following example illustrates the difference between physical and virtual channels and demonstrates how to create virtual channels with the API. Problem Create an NI-DAQmx virtual channel to measure ...

Creating Tasks with the API - NI-DAQmx 17.6 Manual https://www.ni.com/documentation/en/ni-daqmx/17.6/mxcncpts/createtaskapi/
The following example illustrates how to create a task with the API: Problem Create an NI-DAQmx task to measure temperature in the range 50°C to 200°C using a J-type thermocouple that is wired to channel ...

DAQmx Adjust SCXI Calibration (1102) (G Dataflow) - NI-DAQmx 17.6 Manual https://www.ni.com/documentation/en/ni-daqmx/17.6/daqmx-node-ref/daqmx-adjust-scxi-1102-calibrationvi/
Adjusts the external calibration constants for an SCXI-1102 module. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Adjust SCXI 1102 Calibration.vi <helpdir>:/lvdaqmx.chm::/DAQmx ...

DAQmx Adjust C Series Calibration (9207) (G Dataflow) - NI-DAQmx 17.6 Manual https://www.ni.com/documentation/en/ni-daqmx/17.6/daqmx-node-ref/daqmx-adjust-9207-gain-calibrationvi/
Adjusts the external calibration gain constants for an NI 9207 device. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Adjust 9207 Gain Calibration.vi ...

DAQmx Create Virtual Channel (Analog Input » Voltage) (G Dataflow) - NI-DAQmx 17.6 Manual https://www.ni.com/documentation/en/ni-daqmx/17.6/daqmx-node-ref/daqmx-create-channel-ai-voltage-basicvi/
Creates channel(s) to measure voltage. If the measurement requires the use of internal excitation or you need excitation to scale the voltage, use the Custom Voltage with Excitation measurement type for ...

DAQmx Adjust SCXI Calibration (153x) (G Dataflow) - NI-DAQmx 17.6 Manual https://www.ni.com/documentation/en/ni-daqmx/17.6/daqmx-node-ref/daqmx-adjust-scxi-153x-calibrationvi/
Adjusts the external calibration constants for an SCXI-1530 or SCXI-1531 module. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Adjust SCXI 153x Calibration.vi ...

DAQmx Create TEDS Virtual Channel (DAQmx Create Channel (TEDS-AI-Bridge)) (G Dataflow) - NI-DAQmx 17.6 Manual https://www.ni.com/documentation/en/ni-daqmx/17.6/daqmx-node-ref/daqmx-create-channel-teds-ai-bridgevi/
Creates channel(s) that measure a Wheatstone bridge. You must configure the physical channel(s) with TEDS information to use this VI. Use this instance with bridge-based sensors that measure phenomena ...

DAQmx Create Virtual Channel (Analog Input » RVDT) (G Dataflow) - NI-DAQmx 17.6 Manual https://www.ni.com/documentation/en/ni-daqmx/17.6/daqmx-node-ref/daqmx-create-channel-ai-position-rvdtvi/
Creates channel(s) that use(s) an RVDT to measure angular position. LabVIEW NXG does not support FPGA devices Not supported in VIs that run in a web application DAQmx Create Channel (AI-Position-RVDT).vi ...

DAQmx Delete Saved Task (G Dataflow) - NI-DAQmx 17.6 Manual https://www.ni.com/documentation/en/ni-daqmx/17.6/daqmx-node-ref/daqmx-delete-saved-taskvi/
Deletes the specified task from MAX. This node does not clear the copy of the task stored in memory. Use the DAQmx Clear Task node to clear that copy of the task. LabVIEW NXG does not support FPGA devices ...

DAQmx Create Virtual Channel (Counter Input » Pulse Ticks) (G Dataflow) - NI-DAQmx 17.6 Manual https://www.ni.com/documentation/en/ni-daqmx/17.6/daqmx-node-ref/daqmx-create-channel-ci-pulse-ticksvi/
Creates a channel to measure pulse specifications, returning the measurements as pairs of high ticks and low ticks. With the exception of devices that support multi-counter tasks, you can create only one ...