Search Entire Site

  • Search Within

Search Results

Showing 1-10 of 1,955 results
Creating Tasks with the API - NI-DAQmx 18.5 Manual www.ni.com/documentation/en/ni-daqmx/18.5/mxcncpts/createtaskapi/
The following example illustrates how to create a task with the API: Problem Create an NI-DAQmx task to measure temperature in the range 50°C to 200°C using a J-type thermocouple that is wired to channel ...

Creating Virtual Channels with the API - NI-DAQmx 18.5 Manual www.ni.com/documentation/en/ni-daqmx/18.5/mxcncpts/createchansapi/
The following example illustrates the difference between physical and virtual channels and demonstrates how to create virtual channels with the API. Problem Create an NI-DAQmx virtual channel to measure ...

SampClk.DigSync.Enable - NI-DAQmx 18.5 Manual www.ni.com/documentation/en/ni-daqmx/18.5/daqmx-prop-ref/task-sampclk-digsync-enable-2222/
Specifies whether to synchronize recognition of transitions in the signal to the internal timebase of the device. This property does not affect the minimum pulse width recognized by the device, but setting ...

Internal Channels for E Series Devices - NI-DAQmx 18.5 Manual www.ni.com/documentation/en/ni-daqmx/18.5/devconsid/internaleseries/
The following table is a list of internal physical channels for all E Series devices. Different E Series devices have different subsets of channels. These channels are typically for self-calibration, and ...

Common-Mode Over-Range Detection - NI-DAQmx 18.5 Manual www.ni.com/documentation/en/ni-daqmx/18.5/devconsid/commonmodeoverrangedetection/
To determine if a common-mode over-range detection has occurred, use the Common Mode Range Error Channels Exist and Common Mode Range Error Channels properties within the DAQmx Read property node. Common ...

Internal Channels for C Series Devices - NI-DAQmx 18.5 Manual www.ni.com/documentation/en/ni-daqmx/18.5/devconsid/9211interchan/
Internal Channels for the NI 9210 Device Internal Channel Name Description _aignd_vs_aignd A referenced single-ended terminal with the positive and negative terminals both connected to the ground reference ...

Device Routing in MAX - NI-DAQmx 18.5 Manual www.ni.com/documentation/en/ni-daqmx/18.5/mxcncpts/devrouting/
To find the device routing table for your device, launch MAX and select Devices and Interfaces. Click a device to open a tabbed window in the middle pane. Click the Device Routes tab at the bottom of the ...

Configuring a Displacement Measurement with NI-DAQmx - NI-DAQmx 18.5 Manual www.ni.com/documentation/en/ni-daqmx/18.5/mxcncpts/configdisplacmeas/
To configure a measurement, specify the initial sensor position through the Initial Angle attribute/property. You also can specify if the Z Input Terminal is used with the Z Index Enable attribute/property. ...

Platinum RTD Types - NI-DAQmx 18.5 Manual www.ni.com/documentation/en/ni-daqmx/18.5/measfunds/rtdtypes/
The following table lists common platinum RTD types and standards. All of these RTD types are supported in NI-DAQmx. Notice that there are some shared standards. The TCR and the Callendar-Van Dusen coefficients ...

Internal Channels for DSA Devices - NI-DAQmx 18.5 Manual www.ni.com/documentation/en/ni-daqmx/18.5/devconsid/internaldsa/
On a DSA device, you can either acquire a signal present on the I/O connector, or you can acquire a signal that is generated from the internal calibration multiplexer. The channels available on this multiplexer ...