Search Entire Site

  • Search Within

Search Results

Showing 1-10 of 2,037 results
Creating Virtual Channels with the API - NI-DAQmx 19.5 Manual www.ni.com/documentation/en/ni-daqmx/19.5/mxcncpts/createchansapi/
The following example illustrates the difference between physical and virtual channels and demonstrates how to create virtual channels with the API. Problem Create an NI-DAQmx virtual channel to measure ...

Creating Tasks with the API - NI-DAQmx 19.5 Manual www.ni.com/documentation/en/ni-daqmx/19.5/mxcncpts/createtaskapi/
The following example illustrates how to create a task with the API: Problem Create an NI-DAQmx task to measure temperature in the range 50°C to 200°C using a J-type thermocouple that is wired to channel ...

CI.OutputState - NI-DAQmx 19.5 Manual www.ni.com/documentation/en/ni-daqmx/19.5/daqmx-prop-ref/task-ci-outputstate-149/
Indicates the current state of the out terminal of the counter. Not supported Not supported in VIs that run in a web application High 10192 High state. Low 10214 Low state. 149 attr149.html

CI.Period.EnableAveraging - NI-DAQmx 19.5 Manual www.ni.com/documentation/en/ni-daqmx/19.5/daqmx-prop-ref/task-ci-period-enableaveraging-2ed1/
Specifies whether to enable averaging mode for Sample Clock-timed period measurements. Not supported Not supported in VIs that run in a web application 2ED1 attr2ED1.html

CI.Encoder.ZIndexEnable - NI-DAQmx 19.5 Manual www.ni.com/documentation/en/ni-daqmx/19.5/daqmx-prop-ref/task-ci-encoder-zindexenable-890/
Specifies whether to use Z indexing for the channel. Not supported Not supported in VIs that run in a web application 890 attr890.html

CI.Pulse.Freq.Term - NI-DAQmx 19.5 Manual www.ni.com/documentation/en/ni-daqmx/19.5/daqmx-prop-ref/task-ci-pulse-freq-term-2f04/
Specifies the input terminal of the signal to measure. Not supported Not supported in VIs that run in a web application 2F04 attr2F04.html

CI.DutyCycle.Term - NI-DAQmx 19.5 Manual www.ni.com/documentation/en/ni-daqmx/19.5/daqmx-prop-ref/task-ci-dutycycle-term-308d/
Specifies the input terminal of the signal to measure. Not supported Not supported in VIs that run in a web application 308D attr308D.html

CI.SemiPeriod.TermCfg - NI-DAQmx 19.5 Manual www.ni.com/documentation/en/ni-daqmx/19.5/daqmx-prop-ref/task-ci-semiperiod-termcfg-30af/
Specifies the input terminal configuration. Not supported Not supported in VIs that run in a web application Differential 10106 Differential. RSE 10083 Referenced Single-Ended. 30AF attr30AF.html

CI.Encoder.ZIndexPhase - NI-DAQmx 19.5 Manual www.ni.com/documentation/en/ni-daqmx/19.5/daqmx-prop-ref/task-ci-encoder-zindexphase-889/
Specifies the states at which signal A and signal B must be while signal Z is high for NI-DAQmx to reset the measurement. If signal Z is never high while signal A and signal B are high, for example, you ...

CI.Period.DigFltr.MinPulseWidth - NI-DAQmx 19.5 Manual www.ni.com/documentation/en/ni-daqmx/19.5/daqmx-prop-ref/task-ci-period-digfltr-minpulsewidth-21ed/
Specifies in seconds the minimum pulse width the filter recognizes. Not supported Not supported in VIs that run in a web application 21ED attr21ED.html