Fetch (Waveform) (G Dataflow) - NI-DMM 17.0 Manual www.ni.com/documentation/en/ni-dmm/17.0/node-ref/fetch-waveform/
Acquires a waveform and returns data as a waveform data type. The number of points acquired is determined by the Waveform Points parameter in Configure Waveform Acquisition. You must run Initiate before ...

Configure Measurement Complete Slope (G Dataflow) - NI-DMM 17.0 Manual www.ni.com/documentation/en/ni-dmm/17.0/node-ref/configure-meas-complete-slope/
Sets the Measurement Complete signal to either rising edge (positive) or falling edge (negative) polarity. Not supported niDMM Configure Meas Complete Slope.vi <helpdir>:/dmmviref.chm::/niDMM_Configure_Meas_Complete_Slope.html ...

Configure Multi Point (G Dataflow) - NI-DMM 17.0 Manual www.ni.com/documentation/en/ni-dmm/17.0/node-ref/configure-multi-point/
Configures the properties for multipoint measurements. This node sets values for the Trigger Count, Sample Count, Sample Trigger, and Sample Interval properties. For continuous acquisitions, set Trigger ...

Configure Sample Trigger Slope (G Dataflow) - NI-DMM 17.0 Manual www.ni.com/documentation/en/ni-dmm/17.0/node-ref/configure-sample-trigger-slope/
Sets the Sample trigger slope to either rising edge (positive) or falling edge (negative) polarity. Not supported niDMM Configure Sample Trigger Slope.vi <helpdir>:/dmmviref.chm::/niDMM_Configure_Sample_Trigger_Slope.html ...

Configure Offset Compensated Ohms (G Dataflow) - NI-DMM 17.0 Manual www.ni.com/documentation/en/ni-dmm/17.0/node-ref/configure-offset-comp-ohms/
Configures the DMM to compensate for voltage offsets in resistance measurements. When Offset Compensated Ohms is enabled, the DMM measures the resistance twice: once with the current source on, and once ...

Initialize External Calibration (G Dataflow) - NI-DMM 17.0 Manual www.ni.com/documentation/en/ni-dmm/17.0/node-ref/initialize-external-cal/
Creates a new session for external calibration to a specified DMM. Refer to the calibration procedure for your device before running this node. This node resets the DMM and prepares the EEPROM for new ...

Measurement - NI-DMM 17.0 Manual www.ni.com/documentation/en/ni-dmm/17.0/node-ref/measurement/
Acquire data from a measurement.

Get External Calibration Recommended Interval (G Dataflow) - NI-DMM 17.0 Manual www.ni.com/documentation/en/ni-dmm/17.0/node-ref/get-external-cal-interval/
Returns the recommended external calibration interval. Not supported niDMM Get External Cal Recommended Interval.vi <helpdir>:/dmmviref.chm::/niDMM_Get_External_Cal_Recommended_Interval.html session in ...

Disable (G Dataflow) - NI-DMM 17.0 Manual www.ni.com/documentation/en/ni-dmm/17.0/node-ref/disable/
Places the DMM in a quiescent state where it has minimal or no impact on the system to which it is connected. If a measurement is in progress when this node runs, the measurement is aborted. Not supported ...

Configure Thermistor Type (G Dataflow) - NI-DMM 17.0 Manual www.ni.com/documentation/en/ni-dmm/17.0/node-ref/configure-thermistor-type/
Configures the thermistor type. Not supported niDMM Configure Thermistor Type.vi <helpdir>:/dmmviref.chm::/niDMM_Configure_Thermistor_Type.html session in Instrument identifier from previous NI-DMM nodes. ...