Search Entire Site

  • Search Within

Search Results

Showing 1-10 of 100 results
NI-DMM 17.5, 18.0 Manual - NI-DMM 17.5, 18.0 Manual www.ni.com/documentation/en/ni-dmm/17.5/manual/manual-overview/
This manual contains NI-DMM 17.5, 18.0 API reference information for using NI-DMM with LabVIEW NXG to configure and control digital multimeters.

Adjust Gain Calibration (G Dataflow) - NI-DMM 17.5, 18.0 Manual www.ni.com/documentation/en/ni-dmm/17.5/ni-dmm-node-ref/adjust-gain-cal/
Calibrates the gain coefficient for the specified parameters. Refer to the calibration procedure for your DMM before using this node. The calibration procedure contains valid ranges and values for Function ...

Close External Calibration (G Dataflow) - NI-DMM 17.5, 18.0 Manual www.ni.com/documentation/en/ni-dmm/17.5/ni-dmm-node-ref/close-external-cal/
Closes an external calibration session and deallocates reserved resources. Refer to the calibration procedure for your DMM before using this node. Not supported Not supported in VIs that run in a web application ...

Calibration - NI-DMM 17.5, 18.0 Manual www.ni.com/documentation/en/ni-dmm/17.5/ni-dmm-node-ref/calibration/
Calibration NI-DMM 18.1 NI-DMM 18.5, 19.0 Calibrate a DMM. Get Device Temperature Returns the current temperature of the device. Get Self Calibration Supported Checks whether or not a DMM supports self-calibration. ...

Configuration Information - NI-DMM 17.5, 18.0 Manual www.ni.com/documentation/en/ni-dmm/17.5/ni-dmm-node-ref/configuration-information/
Get data about your current DMM configuration.

Commit (G Dataflow) - NI-DMM 17.5, 18.0 Manual www.ni.com/documentation/en/ni-dmm/17.5/ni-dmm-node-ref/commit/
Commits session attributes to hardware. Use this node if you want a parameter change to be immediately reflected in the hardware. Run this node before calling Initiate to make the initiate call as quickly ...

Configure Current Source (G Dataflow) - NI-DMM 17.5, 18.0 Manual www.ni.com/documentation/en/ni-dmm/17.5/ni-dmm-node-ref/configure-current-source/
Configures the current source for diode measurements. Not supported Not supported in VIs that run in a web application Valid values for the current source parameter vary among DMMs. The following table ...

Configure Fixed Reference Junction (G Dataflow) - NI-DMM 17.5, 18.0 Manual www.ni.com/documentation/en/ni-dmm/17.5/ni-dmm-node-ref/configure-fixed-reference-junction/
Configures the fixed reference junction temperature for a thermocouple with a fixed reference junction type. Not supported Not supported in VIs that run in a web application session in Instrument identifier ...

Configure RTD Custom (G Dataflow) - NI-DMM 17.5, 18.0 Manual www.ni.com/documentation/en/ni-dmm/17.5/ni-dmm-node-ref/configure-rtd-custom/
Configures the A, B, and C parameters for a custom RTD. Use this node when the RTD Type parameter of Configure RTD Type is set to 0 (Custom). Not supported Not supported in VIs that run in a web application ...

Configure Thermistor Custom (G Dataflow) - NI-DMM 17.5, 18.0 Manual www.ni.com/documentation/en/ni-dmm/17.5/ni-dmm-node-ref/configure-thermistor-custom/
Configures the A, B, and C parameters for a custom thermistor. Use this node when the thermistor type parameter of Configure Thermistor Type is set to Custom. Not supported Not supported in VIs that run ...