Search Entire Site

  • Search Within

Search Results

Showing 1-10 of 11 results
Identifying PXIe-3610/3630 Module Revision - NI-mmWave 18.1 Manual www.ni.com/documentation/en/ni-mmwave/18.1/manual/identify-module-revision/
To determine which module revision you have of the PXIe-3610 Waveform Generator or PXIe-3630 Digitizer, complete one of the following tasks: Refer to the label on the side of your module; the part number ...

Using the mmWave Transceiver System as a Multichannel Transceiver - NI-mmWave 18.1 Manual www.ni.com/documentation/en/ni-mmwave/18.1/manual/use-mts-as-multichannel-transceiver/
The NI mmWave Reference Project contains an example VI that demonstrates how to use the mmWave Transceiver System as a multichannel transceiver. Before running the VI, examine the hardware setup and ensure ...

Amplitude Corrections - NI-mmWave 18.1 Manual www.ni.com/documentation/en/ni-mmwave/18.1/manual/amplitude-corrections/
You can configure the analog gain on both the receiver (RX) and transmitter (TX) signal paths with the NI-mmWave Configuration API. Corrections are applied based on device characteristics stored on the ...

Fast Configuration Overview - NI-mmWave 18.1 Manual www.ni.com/documentation/en/ni-mmwave/18.1/manual/fast-configuration-overview/
The mmWave Transceiver System supports fast configuration of gain and mmWave port switches. The PXIe-7902 High-Speed Serial Instrument can send commands to the PXIe-3620 RF Upconverter and Downconverter ...

Fast Gain Ranging - NI-mmWave 18.1 Manual www.ni.com/documentation/en/ni-mmwave/18.1/manual/fast-gain-ranging/
You can set a rough gain very quickly and adjust to an exact gain slightly later by using fine gain ranging and coarse gain ranging together. The benefits of using fine gain ranging and coarse gain ranging ...

Fast mmWave Port Switching - NI-mmWave 18.1 Manual www.ni.com/documentation/en/ni-mmwave/18.1/manual/fast-mmwave-port-switching/
You can configure the mmRH-3602/3603 to route mmWave signals to and/or from one of the following two mmRH-3602/3603 radio head antenna ports: TX1/RX1 and RX2. Use the NI mmWave Reference Project and the ...

LO Sharing - NI-mmWave 18.1 Manual www.ni.com/documentation/en/ni-mmwave/18.1/manual/lo-sharing/
You can configure the PXIe-3620 RF Upconverter and Downconverter Module module to use an external local oscillator (LO) signal when preparing the signal for upconversion or downconversion. You can configure ...

NI-mmWave Configuration API - NI-mmWave 18.1 Manual www.ni.com/documentation/en/ni-mmwave/18.1/manual/ni-mmwave-configuration-api/
scope Input Most VIs in the NI-mmWave Configuration API require a scope input string. This string specifies the scope of the configuration for the VI. Each VI has a unique set of valid values for this ...

Synchronization Overview - NI-mmWave 18.1 Manual www.ni.com/documentation/en/ni-mmwave/18.1/manual/synchronization-overview/
Synchronization occurs between all baseband transmitters and baseband receivers in your system so that generation and acquisition can begin on the FPGA during the same cycle. For example, in the bidirectional ...

System Calibration Utility - NI-mmWave 18.1 Manual www.ni.com/documentation/en/ni-mmwave/18.1/manual/system-calibration-utility/
The system calibration utility is included in the NI mmWave Reference Project. This utility calibrates the system by measuring in-phase/quadrature (I/Q) impairments for each channel. To use this utility, ...