Search Entire Site

  • Search Within

Search Results

Showing 1-10 of 131 results
NI-SCOPE Soft Front Panel and InstrumentStudio - NI-SCOPE 19.1, 19.5 Manual www.ni.com/documentation/en/ni-scope/19.1/manual/sfp-instrumentstudio/
When you install NI-SCOPE on a 64-bit system, you can monitor, control, and record measurements from supported devices using InstrumentStudio. InstrumentStudio is a software-based front panel application ...

Adjust Accessory Gain and Offset Calibration (G Dataflow) - NI-SCOPE 19.1, 19.5 Manual www.ni.com/documentation/en/ni-scope/19.1/scopenodes/adjust-accessory-gain-and-offset-calibration/
For the PXI-5900 PXI RF Amplifier, this node calibrates the gain and offset. Not supported Not supported in VIs that run in a web application session in The instrument handle that you obtain from Initialize ...

CableSense Signal Stop (G Dataflow) - NI-SCOPE 19.1, 19.5 Manual www.ni.com/documentation/en/ni-scope/19.1/scopenodes/cablesense-signal-stop/
Disables the CableSense signal on all channels of an oscilloscope for which the signal is enabled. Not supported Not supported in VIs that run in a web application This node supports the following hardware: ...

Close (G Dataflow) - NI-SCOPE 19.1, 19.5 Manual www.ni.com/documentation/en/ni-scope/19.1/scopenodes/close/
Ends an niScope instrument I/O session and performs closing actions. This function performs the following actions: Closes the instrument I/O session. Destroys the IVI session and all of its properties ...

Close External Calibration (G Dataflow) - NI-SCOPE 19.1, 19.5 Manual www.ni.com/documentation/en/ni-scope/19.1/scopenodes/close-external-calibration/
Closes an external calibration session. You must call this node each time you call Initialize External Calibration, even if an error occurs during calibration. Not supported Not supported in VIs that run ...

Configure Clock (G Dataflow) - NI-SCOPE 19.1, 19.5 Manual www.ni.com/documentation/en/ni-scope/19.1/scopenodes/configure-clock/
Configures the properties for synchronizing the digitizer to an external clock or sending the digitizer's clock output to be used as a synchronizing clock for other devices. Not supported Not supported ...

Configure Trigger (Immediate) (G Dataflow) - NI-SCOPE 19.1, 19.5 Manual www.ni.com/documentation/en/ni-scope/19.1/scopenodes/configure-trigger-immediate/
Configures common properties for immediate triggering. Immediate triggering means the digitizer triggers itself. Not supported Not supported in VIs that run in a web application This node does not support ...

Export Attribute Configuration - NI-SCOPE 19.1, 19.5 Manual www.ni.com/documentation/en/ni-scope/19.1/scopenodes/export-attribute-configuration/
Exports the attribute configuration of a session to either a file or a buffer.

Fetch Measurement (Array » Single » Cluster) (G Dataflow) - NI-SCOPE 19.1, 19.5 Manual www.ni.com/documentation/en/ni-scope/19.1/scopenodes/fetch-measurement-array-single-cluster/
Obtains a waveform from the digitizer and returns the specified measurement array for a single channel and record as a cluster along with timing data. Not supported Not supported in VIs that run in a web ...

Fetch Measurement (Stats » Single) (G Dataflow) - NI-SCOPE 19.1, 19.5 Manual www.ni.com/documentation/en/ni-scope/19.1/scopenodes/fetch-measurement-stats-single/
Obtains a waveform measurement and returns the measurement value for a single channel and record. You can specify a particular measurement type, such as rise time, frequency, or voltage peak-to-peak. The ...