Why Doesn't the Device Power On? - NI-USRP 19.0, 19.1, and 19.5 www.ni.com/documentation/en/ni-usrp/19.0/manual/device-power-on/
Verify that the power supply is functional by substituting a different adapter. Verify that the power switch on the front of the device is engaged.

Accessing Properties - NI-USRP 19.0, 19.1, and 19.5 www.ni.com/documentation/en/ni-usrp/19.0/manual/accessing-properties/
In LabVIEW, LabVIEW NXG, and LabVIEW Communications System Design Suite, you can find properties in niUSRP Properties. To access them, complete the following steps: Open a block diagram. Navigate to the ...

Configuring Multiple Devices - NI-USRP 19.0, 19.1, and 19.5 www.ni.com/documentation/en/ni-usrp/19.0/manual/configuring-multiple-devices/
You can connect multiple devices in the following ways: Multiple Ethernet interfaces—one device for each interface Single Ethernet interface—one device connected to the interface, additional device connected ...

Why Doesn't the USRP Device Appear in the NI-USRP Configuration Utility? - NI-USRP 19.0, 19.1, and 19.5 www.ni.com/documentation/en/ni-usrp/19.0/manual/device-appear-in-config-utility/
Check the connection between the USRP device and the computer. Ensure that the USRP device is powered on and connected to a computer before you power on the computer.

Why Do I Receive an Enumeration Error? - NI-USRP 19.0, 19.1, and 19.5 www.ni.com/documentation/en/ni-usrp/19.0/manual/enumeration-error/
If you are using a desktop computer with the NI-USRP instrument driver installed, it is possible that there is a compatibility issue between your computer and the PCIe card. Complete the following steps ...

Using NI-USRP in LabVIEW NXG and LabVIEW Communications System Design Suite - NI-USRP 19.0, 19.1, and 19.5 www.ni.com/documentation/en/ni-usrp/19.0/manual/using-ni-usrp-nxg-comms/
Complete the following steps to develop an NI-USRP application in LabVIEW NXG or LabVIEW Communications System Design Suite: Open an existing or new VI. Select the Diagram tab. From the palette, locate ...

Why Doesn't the USRP Device Appear in MAX? - NI-USRP 19.0, 19.1, and 19.5 www.ni.com/documentation/en/ni-usrp/19.0/manual/appear-max-usrp-device/
MAX only supports USRP-2940/2942/2943/2944/2945 and USRP-2950/2952/2953/2954/2955 devices configured with a PCI Express connection. If you are using a USRP device configured with an Ethernet connection, ...

Using NI-USRP in LabVIEW - NI-USRP 19.0, 19.1, and 19.5 www.ni.com/documentation/en/ni-usrp/19.0/manual/using-labview/
Complete the following steps to develop an NI-USRP application in LabVIEW: Open an existing or new VI. From the Functions palette, locate the NI-USRP VIs at Instrument I/O Instrument DriverNI-USRP. Select ...

Configuring an MTU Size Greater than 1,500 Bytes - NI-USRP 19.0, 19.1, and 19.5 www.ni.com/documentation/en/ni-usrp/19.0/manual/configuring-mtu-greater-than-1500-bytes/
To configure a maximum transmission unit (MTU) size greater than 1,500 bytes, complete the following steps: Enable the jumbo frames option of the Ethernet interface card. Select Control PanelNetwork and ...

Increasing the Number of Samples - NI-USRP 19.0, 19.1, and 19.5 www.ni.com/documentation/en/ni-usrp/19.0/manual/increasing-number-of-samples/
Increase the number of samples to achieve greater throughput in Ethernet- and PCIe-based streaming. Complete the following procedure to improve data streaming performance: Increase the number of samples ...