Search Entire Site

  • Search Within

Search Results

Showing 1-10 of 12 results
Clocking - Transceiver Adapter Module for FlexRIO www.ni.com/documentation/en/transceiver-adapter-module-for-flexrio/latest/ni-5782/clocking/
The NI-5782 clock source controls the sample rate and other timing functions on the device. The following table contains information about the possible NI-5782 clock sources. NI-5782 Clock Sources Clock ...

NI-5782 - Transceiver Adapter Module for FlexRIO www.ni.com/documentation/en/transceiver-adapter-module-for-flexrio/latest/ni-5782/overview/
100 MHz bandwidth transceiver adapter module for FlexRIO. Dual 14-bit, 250 MS/s inputs Dual 16-bit, 500 MS/s real-time, 1 GS/s interpolated outputs 100 MHz real-time bandwidth per channel DC- and AC-coupled ...

User Data Clock Settings - Transceiver Adapter Module for FlexRIO www.ni.com/documentation/en/transceiver-adapter-module-for-flexrio/latest/ni-5782/user-data-clock/
Configure the DAC output at runtime by providing the appropriate User Data 1 value from the User Data Clock Settings table. Timebase Clock—The Timebase Clock is routed to the ADC and the DAC, and is used ...

User Data Clock Settings - Transceiver Adapter Module for FlexRIO www.ni.com/documentation/en/transceiver-adapter-module-for-flexrio/latest/ni-5782/5782-multisamp-user-data/
Configure the DAC output at runtime by providing the appropriate User Data 1 value from the User Data Clock Settings table. Timebase Clock—The Timebase Clock is routed to the ADC and the DAC, and is used ...

NI-5782 Specifications - Transceiver Adapter Module for FlexRIO www.ni.com/documentation/en/transceiver-adapter-module-for-flexrio/latest/specs-ni-5782/specs/
This document lists specifications for the NI-5782. All specifications are subject to change without notice. The protection provided by the NI-5782 can be impaired if it is used in a manner not described ...

User Command Reference - Transceiver Adapter Module for FlexRIO www.ni.com/documentation/en/transceiver-adapter-module-for-flexrio/latest/ni-5782/user-command-multisample/
User Setting User Command User Data 0 Value User Data 1 Value User Return Value Clock Settings 0 0 = Internal Sample Clock 1 = Internal Sample Clock locked to an external Reference Clock through the CLK ...

Block Diagram - Transceiver Adapter Module for FlexRIO www.ni.com/documentation/en/transceiver-adapter-module-for-flexrio/latest/ni-5782/block-diagram/
The following figure shows the NI-5782 block diagram and signal flow. NI-5782 Connector Signals and NI-5782 CLIP Signal Block Diagram

User Command Reference - Transceiver Adapter Module for FlexRIO www.ni.com/documentation/en/transceiver-adapter-module-for-flexrio/latest/ni-5782/user-command/
User Setting User Command User Data 0 Value User Data 1 Value User Return Value Clock Settings 0 0 = Internal Sample Clock 1 = Internal Sample Clock locked to an external Reference Clock through the CLK ...

NI-5782 Multi-Sample CLIP I/O Reference - Transceiver Adapter Module for FlexRIO www.ni.com/documentation/en/transceiver-adapter-module-for-flexrio/latest/ni-5782/5782-multisample-clip/
CLIP Signal Name Data Type Control/Indicator Description CLK200 — — You must select a 200 MHz clock in the Clock Selections category of the IO Module Properties dialog box for proper CLIP functionality. ...

NI-5782 Front Panel - Transceiver Adapter Module for FlexRIO www.ni.com/documentation/en/transceiver-adapter-module-for-flexrio/latest/ni-5782/5782-pinout/
NI-5782 Front Panel Connectors Device Front Panel Connector Signal Description AUX I/O Digital I/O and PFI connector CLK IN 50 Ω single-ended (SE) external Reference or Sample Clock input. TRIG Trigger ...