FD-11601 Block Diagram - Voltage Input Device for FieldDAQ Manual www.ni.com/documentation/en/voltage-input-device-for-fielddaq/latest/fd-11601/block-diagram/
FD-11601 Input Circuitry FD-11601 Block Diagram

FD-11605 Front Panel - Voltage Input Device for FieldDAQ Manual www.ni.com/documentation/en/voltage-input-device-for-fielddaq/latest/fd-11605/pinout/
Front PanelPower IN ConnectorPower LEDEthernet Port 0 and LEDBank 1 Voltage Input Connectors 0 through 3 and LEDsBank 2 Voltage Input Connectors 0 through 3 and LEDsMounting HolesPower OUT ConnectorSTATUS ...

AI Sample Clock Signal - Voltage Input Device for FieldDAQ Manual www.ni.com/documentation/en/voltage-input-device-for-fielddaq/latest/manual/ai-sample-clock-signal/
Use this topic version for devices supported in NI-DAQmx 18.1 or earlier. A sample consists of one reading from each channel in the AI task. Sample Clock signals the start of a sample of all analog input ...

AI Sample Clock Timebase Signal - Voltage Input Device for FieldDAQ Manual www.ni.com/documentation/en/voltage-input-device-for-fielddaq/latest/manual/ai-sample-clock-timebase-signal/
The AI Sample Clock Timebase signal is divided down to provide a source for Sample Clock.

AI Start Trigger Signal - Voltage Input Device for FieldDAQ Manual www.ni.com/documentation/en/voltage-input-device-for-fielddaq/latest/manual/ai-start-trigger-signal/
Use the Start Trigger signal to begin a measurement acquisition. A measurement acquisition consists of one or more samples. If you do not use triggers, begin a measurement with a software command. Once ...

Alternate Mounting Configurations - Voltage Input Device for FieldDAQ Manual www.ni.com/documentation/en/voltage-input-device-for-fielddaq/latest/manual/alternate-mounting-configurations/
The maximum operating temperature of 85 °C may be reduced for any mounting configuration other than the reference mounting configuration. A 10 °C (18 °F) reduction in maximum operating temperature is sufficient ...

Analog Input Sync Pulse - Voltage Input Device for FieldDAQ Manual www.ni.com/documentation/en/voltage-input-device-for-fielddaq/latest/manual/analog-input-sync-pulse/
You can use time as a trigger for sync pulses on the FieldDAQ device. To use a sync pulse with a time source, specify a specific time in NI-DAQmx. Refer to the Time Triggering topic in the NI-DAQmx Help ...

Connecting External Sensors - Voltage Input Device for FieldDAQ Manual www.ni.com/documentation/en/voltage-input-device-for-fielddaq/latest/manual/connecting-external-sensors/
You can power a 3- or 4-wire external sensor with an output voltage range of 5 V to 24 V by connection through the sensor power (SP) and ground (GND) terminals on the FieldDAQ device. The output voltage ...

Connecting TEDS Sensors - Voltage Input Device for FieldDAQ Manual www.ni.com/documentation/en/voltage-input-device-for-fielddaq/latest/manual/connecting-teds-sensors/
You can connect TEDS (Transducer Electronic Data Sheets) sensors to the FieldDAQ device through the T+ and T- pins on each connector. Connecting TEDS Sensors to the FieldDAQ Device

Connecting Voltage Input Signals - Voltage Input Device for FieldDAQ Manual www.ni.com/documentation/en/voltage-input-device-for-fielddaq/latest/manual/connecting-voltage-input-signals/
You can connect grounded and floating voltage input signals to the FieldDAQ device. Make sure that devices you connect to the FieldDAQ device are compatible, as listed in the FD-116xx Specifications. Grounded ...