Search Results

Showing 1-10 of 11 results
SCC Example Series: SCC-SG0x www.ni.com/example/27534/en/
These examples are intended for use with the SCC Tutorial Series: SCC-SG0x document. The examples acquire data from a single strain gauge virtual channel using one of the SCC-SG0x ...
Rating: 2.33 Last Modified: February 23 2007 Download Example

Can I Use Remote Sense with the SCXI-1520 Configured for Quarter-Bridge Measurements? digital.ni.com/public.nsf/allkb/DDA796448F12FE0F862573FD006F53E2
I am using the SCXI-1520 to perform quarter-bridge strain gage measurements.  Since I have long leads connecting the strain gages to the SCXI-1520, I would like to use remote sense to eliminate error introduced ...

How Can I Test a Device that Requires Excitation in MAX? digital.ni.com/public.nsf/allkb/C2553DEE2E3CF1BE862573A30062C1F3
I am testing my SCXI device using test panels in Measurement & Automation Explorer (MAX) but the values aren't what I'm expecting. Is something wrong with my device?

What SCC Modules are Supported by the SCC-68? digital.ni.com/public.nsf/allkb/4592E570D078320886257211000C7CF0
This Document is not yet Rated What SCC Modules are Supported by the SCC-68? Hardware: SCC>>Modules, Multifunction DAQ (MIO)>>Connector Blocks>>SCC-68 Problem: Does the SCC-68 support every available National ...

SCC Modules in SCC-68 Rail digital.ni.com/public.nsf/allkb/28FDBEE244472A408625714100803DC9
When I try to read an analog input signal through an SCC module in a SCC-68 terminal block, the signal appears to rail. For example, when trying to read a 0-20mA current through a SCC-CI20 module, it always ...

What do the Color Strips on SCC Modules Indicate? digital.ni.com/public.nsf/allkb/886FABB22CEBF56A86257083007BC34A
2 ratings:   3 out of 5    What do the Color Strips on SCC Modules Indicate? Hardware: SCC>>Modules Problem: SCC modules have color-coded strips on their labels. What do these colors indicate? Solution: ...

How Do the Module Slots on the SC-2345 Map to the Channels on the DAQ Cards? digital.ni.com/public.nsf/allkb/1D49E47CB61CE52486256F95001A740A
Whenever I configure my SC-2345 and add the SCC modules to the slots, the channel number that appears right next to the module doesn't match to the channel numbers appearing when configuring a Task for ...

How Do I Use an External Excitation Source with an SCC-SG0x Module? digital.ni.com/public.nsf/allkb/1EE18E5A736C7F6986256A3F00547E70
The SCC Series User Manual states that I can use an external source to provide the excitation for my SCC-SG0x strain gage module. How to I connect the external excitation signal? Will the offset nulling ...

Archived: On Demand Sampling with SCXI Modules Causes Incorrect Measurements digital.ni.com/public.nsf/allkb/F964B09ABC4529998625775F007C5F29
While performing multi-channel, multi-sample, on demand acquisitions with my SCXI-1122 analog input module, I see incorrect measurements on some of the channels that I am reading.  Is there something I ...

Archived: Why Do I Receive Error -200619 When Trying To Acquire Data With Multiple SCXI Modules? digital.ni.com/public.nsf/allkb/AD469F16D62851168625723A006DEB12
I am trying to acquire data with multiple National Instruments Data Acquisition cards and multiple SCXI modules in a single chassis.I have connected each card to each module in a parallel configuration ...