Search Entire Site

  • Search Within

Search Results

Showing 1-10 of 384 results
Logging a Data Set - NI ELVIS III 2.2.1 Manual https://www.ni.com/documentation/en/ni-elvis-iii/2.2.1/instrument-ref/logging-a-data-set/
Install the NI ELVIS III prototyping board onto the NI ELVIS III workstation. Connect a jumper wire between Bank A, Channel AI0 (A/AI0) and A/AO0, and between A/AI1 and A/AO1. Refer to Connecting Signals ...

Updating Firmware on the Device - NI ELVIS III 2.2.1 Manual https://www.ni.com/documentation/en/ni-elvis-iii/2.2.1/getting-started/updating-firmware-on-device/
MAX is installed automatically when you install the NI ELVIS III Software Bundle or the LabVIEW ELVIS III Toolkit. Complete the following steps to update firmware on the NI ELVIS III using MAX: Obtain ...

Generating a Waveform (Data Generator) - NI ELVIS III 2.2.1 Manual https://www.ni.com/documentation/en/ni-elvis-iii/2.2.1/instrument-ref/generating-static-triangle-wave/
Install the NI ELVIS III prototyping board onto the NI ELVIS III workstation. Connect a jumper wire between Bank A, Channel AO0 (A/AO0) and the circuit under test, and between Bank A, AGND and GND of the ...

Installing Software on the Device - NI ELVIS III 2.2.1 Manual https://www.ni.com/documentation/en/ni-elvis-iii/2.2.1/getting-started/installing-software-on-elvis-iii/
MAX is installed automatically when you install the NI ELVIS III Software Bundle or the LabVIEW ELVIS III Toolkit. Complete the following steps to install software on the NI ELVIS III using MAX: In MAX, ...

Generating a Waveform - NI ELVIS III 2.2.1 Manual https://www.ni.com/documentation/en/ni-elvis-iii/2.2.1/instrument-ref/generating-a-sweep-sine-wave/
The procedure for generating other types of waveforms is similar. Refer to the Configuration Options (FGen/Arb) section to learn about other generation modes. Connect a BNC cable between Function Generator ...

Programming the Digital Multimeter - NI ELVIS III 2.2.1 Manual https://www.ni.com/documentation/en/ni-elvis-iii/2.2.1/instrument-ref/programming-the-dmm/
Programming the Digital Multimeter NI ELVIS III 1.0 NI ELVIS III 1.2 NI ELVIS III 2.0 NI ELVIS III 2.1 NI ELVIS III 2.2 You can use the Digital Multimeter VIs installed with the LabVIEW ELVIS III Toolkit ...

Using the Soft Front Panels - NI ELVIS III 2.2.1 Manual https://www.ni.com/documentation/en/ni-elvis-iii/2.2.1/getting-started/using-soft-front-panels/
Connect a BNC - BNC cable between the Oscilloscope CH 1 and the Function Generator CH 1 BNC connectors on the NI ELVIS III as shown in the following diagram: Select Function and Arbitrary Waveform Generator ...

Programming the Logic Analyzer and Pattern Generator - NI ELVIS III 2.2.1 Manual https://www.ni.com/documentation/en/ni-elvis-iii/2.2.1/instrument-ref/programming-the-logic/
Programming the Logic Analyzer and Pattern Generator NI ELVIS III 1.0 NI ELVIS III 1.2 NI ELVIS III 2.0 NI ELVIS III 2.1 NI ELVIS III 2.2 You can use the Logic Analyzer and Pattern Generator VIs installed ...

Analyzing a BJT - NI ELVIS III 2.2.1 Manual https://www.ni.com/documentation/en/ni-elvis-iii/2.2.1/instrument-ref/analyzing-a-bjt/
Complete the following steps to run current-voltage (IV) analyses for a BJT: Launch the IV Analyzer Soft Front Panel (SFP). Select Transistor under Analyzer mode. Connect a BJT to the IV ANALYZER terminals ...

Controlling the LED with Digital I/O - NI ELVIS III 2.2.1 Manual https://www.ni.com/documentation/en/ni-elvis-iii/2.2.1/instrument-ref/control-led/
Install the NI ELVIS III prototyping board onto the NI ELVIS III workstation. Connect a jumper wire between Bank A, Channel DIO 0 (A/DIO 0) and LED 0, as shown in the following diagram: Refer to Connecting ...